{"id":"GHSA-76x4-hr82-cg3m","summary":"Jenkins ElectricFlow Plugin cross-site request forgery vulnerability","details":"A missing permission check in a form validation method in CloudBees CD Plugin allowed users with Overall/Read permission to initiate a connection test to an attacker-specified server with attacker-specified username and password.\n\nAdditionally, the form validation method did not require POST requests, resulting in a CSRF vulnerability.\n\nThis form validation method now requires POST requests and Overall/Administer permissions.","aliases":["CVE-2019-10331"],"modified":"2024-02-16T08:40:05.813412Z","published":"2022-05-24T16:47:43Z","database_specific":{"severity":"MODERATE","github_reviewed":true,"github_reviewed_at":"2023-10-26T22:28:30Z","nvd_published_at":"2019-06-11T14:29:00Z","cwe_ids":["CWE-352"]},"references":[{"type":"ADVISORY","url":"https://nvd.nist.gov/vuln/detail/CVE-2019-10331"},{"type":"WEB","url":"https://jenkins.io/security/advisory/2019-06-11/#SECURITY-1410%20(1)"},{"type":"WEB","url":"https://web.archive.org/web/20200227033720/http://www.securityfocus.com/bid/108747"},{"type":"WEB","url":"http://www.openwall.com/lists/oss-security/2019/06/11/1"}],"affected":[{"package":{"name":"org.jenkins-ci.plugins:electricflow","ecosystem":"Maven","purl":"pkg:maven/org.jenkins-ci.plugins/electricflow"},"ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"fixed":"1.1.7"}]}],"versions":["1.0","1.1.1","1.1.2","1.1.3","1.1.4","1.1.5","1.1.6"],"database_specific":{"last_known_affected_version_range":"\u003c= 1.1.6","source":"https://github.com/github/advisory-database/blob/main/advisories/github-reviewed/2022/05/GHSA-76x4-hr82-cg3m/GHSA-76x4-hr82-cg3m.json"}}],"schema_version":"1.9.0","severity":[{"type":"CVSS_V3","score":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N"}]}